Uplink noise rise on a shared DAS: diagnosing passive intermodulation

Stationary test point in a building covered by a shared multi-operator DAS, LTE band 20 (800 MHz), uplink, downlink and simultaneous tests.

Verification

Before/after comparison

KPIBeforeAfter
PUSCH power, simultaneous test23 dBm11 dBm
UL throughput, simultaneous test1.0 Mbit/s15.5 Mbit/s
UL retransmissions, simultaneous test19%3%
Allocated UL RBs, simultaneous test640
DL throughput, simultaneous test36 Mbit/s53 Mbit/s
Correlation of DL throughput with PUSCH power0.93−0.37

Typical scenario replayed in AKCELL Analyzer on demonstration data; the values are those computed by the tool on these sessions.